| Content | PDF |
Zip |
Zip |
| Complete Insul-Flex WaterMaster System Details |
PDF |
DWG |
DXF |
General Construction
- IFWM G1.01 LaHabra Insul-Flex WaterMaster Components
- IFWM G1.01A LaHabra Insul-Flex WaterMaster System Components
- IFWM G1.02 Framed Wall Application
- IFWM G1.03 Window Flashing Procedure
- IFWM G1.03A Alternate Window Flashing Procedure
- IFWM G1.04 Preliminary Mesh Application
- IFWM G1.05 Inside Corner
- IFWM G1.06 Outside Corner
|
PDF |
DWG |
DXF |
Expansion Joints
- IFWM E1.01 Inside Corner at Dissimilar Substrates
- IFWM E1.02 Thru-system Flashing with Weeps
- IFWM E1.03 Dissimilar Substrates
- IFWM E1.04 Framed Sill (non-residential)
- IFWM E1.05 Floor Line Expansion (non-residential)
- IFWM E1.06 Expansion Joint
|
PDF |
DWG |
DXF |
Terminations
- IFWM T1.01 Termination Above Pavement
- IFWM T1.01A Backwrapped Termination Above Pavement
- IFWM T1.02 Termination Above Grade
- IFWM T1.02A Backwrapped Termination Above Grade
- IFWM T1.03 Cladding Transition
- IFWM T1.04 System Termination at Vertical Edge
- IFWM T1.05 Termination at Balcony Deck
|
PDF |
DWG |
DXF |
Windows
- IFWM W1.01 Backwrapped Jamb
- IFWM W1.02 Termination at Flush / Projecting Jamb
- IFWM W1.03 Backwrapped Sill
- IFWM W1.04 Head Termination
- IFWM W1.05 Termination at Metal Flashed Window Sill
- IFWM W1.06 Backwrapped Termination at Sill
|
PDF |
DWG |
DXF |
Roof Line
- IFWM R1.01 Termination at Box Cornice
- IFWM R1.02 Termination at Soffit
- IFWM R1.03 Parapet
- IFWM R1.05 Gravel Stop
- IFWM R1.06 Chimney Flashing System Detail
- IFWM R1.07 Insulated Soffit
- IFWM R1.08 Termination at Fascia / Soffit
- IFWM R1.09 Intersection of Roof Cornice at System Wall
- IFWM R1.09A Backwrapped Intersection of Roof Cornice at System Wall
- IFWM R1.09B Intersection of Roof Cornice at System Wall
|
PDF |
DWG |
DXF |
Pentetrations
- IFWM P1.01 Fixture Attachment (by others)
- IFWM P1.02 Hose Bib (by others)
- IFWM P1.03 Downspout Attachment (by others)
- IFWM P1.04 Termination at Dryer Vent (by others)
- IFWM P1.05 Termination at Appliance Sleeve (by others)
- IFWM P1.06 Termination at Small Electrical Feature (by others)
- IFWM P1.07 Deck Attachment (by others)
- IFWM P1.08 Handrail Attachment (by others)
|
PDF |
DWG |
DXF |
Aesthetic Features
- IFWM A1.01 Aesthetic Groove / Reveal
- IFWM A1.02 Small Aesthetic Band / Projection
|
PDF |
DWG |
DXF |
Disclaimer: The design specifications and construction of the wall
shall comply with all building codes and standards. Parex USA installation guidelines are for general information and guidance only and
Parex USA specifically disclaims all liability for the use of this design, for design engineering, and for workmanship of any project.
The wall assembly shall be designed to prevent condensation within the assembly. The designer and the user shall provide final drawings
and specifications.
The drawings and any related notes or text contained thereon, are based upon typical requirements of LaHabra exterior insulation
and finish systems and are published strictly as a guide for architectural and construction industry professionals to illustrate
typical or general design conditions.
These details are not to be used by themselves, and do not constitute design instructions for LaHabra EIFS application. These
details must be used in conjunction with LaHabra current product specifications, product data sheets, and application instructions.
Any details shown are strictly for the purpose of illustrating typical LaHabra EIFS. Any other materials shown in any details are
incidental to the details, and are included only for clarity of the LaHabra EIFS. Please consult with the manufacturers and/or
suppliers of any separate materials for their product specifications and applications instructions.
Where site or design conditions not shown in these details are present, or any unusual design is involved, please consult with the
Parex USA Technical Department for assistance.
PAREX USA DOES NOT WARRANT THE FITNESS OF SUITABILITY OF THESE DETAILS FOR CONSTRUCTION, OR ASSUME ANY LIABILITY FOR USE OF THESE
DETAILS. IT IS THE SOLE RESPONSIBILITY OF ANY ARCHITECTURAL OR CONSTRUCTION INDUSTRY PROFESSIONAL TO APPLY THEIR PROFESSIONAL KNOWLEDGE
IN UTILIZING THE INFORMATION CONTAINED IN THESE DETAILS.